AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Aft Impulse User Manual4/28/2021
Piper refrigerant oil PMS-L2000 or equivalent 500 viscosity refrigerant oil must be used.Evacuate and charge system.Per Paragraphs 14-13 and 14-14.) NOTE The 10 ounce oil level is required in compressors installed on new systems.
Applied Flow Technology Impulse allows you to create a project-design of the pipeline system with a greater degree of security, reliability and safety, eliminating the potentially dangerous effects of water hammer and other undesired unsteady modes. We aim to close the gap to the industry by improving the awareness about latest trends in Civil Engineering. Applied Flow Technology Impulse allows you to create a project design of a pipeline system with a greater degree of protection, reliability and safety eliminating the potentially dangerous effects of water hammer and other undesirable transient conditions. Maximum Uer Weight: 120kg Chain Drive System Crank: 3 pc, Welded Chain Ring, Ratio 1:3.03 Brake: Side Pull design including Push Down Emergency Stop,can be top brake Pedals: Deluxe Steel Cage Aluminum body with Toe Cage and Strap. Seat Post Asm: Height and Fore Aft adjustment via Clamping Pop Pin Handlebar: Height adjustment via Clamping Pop Pin Water Bottle: Meets China Food Standards, Cage included Transportation Wheels for easy moving of the bike English User Manual and, Assembly Tools included Low Maintenance and easy assembly Basis G.W. N.W.: 50.5KGS 45KGS. Assembled Size: 1230 x 505 x 1220mm Carton Size: 1025 x 250 x 870mm Packaging: Carton Foam, meets Drop Test Standards Container Loading: 122PCS20FCL, 258PCS40FCL, 307PCS40HQ. Aft Impulse User Software To BeCommercial software to be used for safety related applications is considered a basic component, and as such must undergo a Commercial Grade Dedication (CGD). ASME NQA-1 provides guidance on verifying software for safety related use. EPRI Report 1025243 provides guidance on performing a CGD for software. More about Commercial Grade Dedication Applied Flow Technology sells Fathom (incompressible flow), Arrow (compressible flow) and Impulse (transient flow), which are commercial flow software packages for the analysis of piping systems. AFT provides these packages with several optional add on modules to expand the functionality of the program. Fathom, Arrow and Impulse are provided as commercial grade packages. ![]() These packages were developed under Archons 10CFR50 Appendix B, and ASME NQA-1, 1994 QA program. Thus, Archon is able to provide these packages via a Nuclear Safety Related Purchase Order to nuclear clients. These packages provide verification of the software as well as Safety Classification, Failure Modes and Effects Analysis, and a determination of the Critical Characteristics. ![]() Aft Impulse User Update The VVPricing The initial fees will entitle the customer to updates to the VV package for one year (Archon will typically update the VV package approximately twice a year to the latest version at that time). The initial fees are: Fathom (Basic Module): 24,000 Fathom GSC Module (optional): 3,000 Fathom XTS Module (optional): 3,000 Arrow (Basic Module): 30,000 Arrow GSC Module (optional): 3,600 Impulse: 36,000 A subscription is available to maintain upgrades beyond the first year. The cost for the subscriptions are: Fathom (Basic Module): 7,200 Fathom GSC Module (optional): 600 Fathom XTS Module (optional): 600 Arrow (Basic Module): 9,000 Arrow GSC Module (optional): 600 Impulse: 10,800 The VV package is considered proprietary and may only be copied and distributed for the users internal use at a single site. For use at additional sites, VV package is available at a 50 discount of the above prices. Fathom VV Package Details The VV report will as a minimum verify the following: The following Fathom Database files are accurate for pipe sizes (diameters, thickness) and pipe roughness: Steel ANSI.dat Stainless Steel ANSI.dat Stainless Tubing AFT Customary.dat PVC ASTM.dat Ductile Iron ANSI.dat Copper Tubing ASTM.dat Copper Pipe ASTM.dat PVDF AFT Customary.dat HDPE AFT Customary.dat Fathoms database file Fathom10.dat is accurate for the following items: Steam and Water properties (density, viscosity, vapor pressure) Fitting loss data That flow, and pressures are accurately calculated using Fathoms pipe and junction features. Aft Impulse User Manual Calculations ForEach junction type will be checked against manual calculations for the different user options provided by Fathom. Heat Transfer (Fluid and pipe wall temperatures, heat rate, heat flux, etc.) are accurately calculated from user supplied thermo-physical data (i.e. The Goal Seek and Control (GSC) module will be evaluated to determine that it produces correct and accurate results for the different Goal and Variable options Fathom provides (optional for GSC module only) The Extended Time Simulation (XTS) module will be evaluated to determine it produces correct and accurate results for the time triggering scenarios that Fathom provides (optional for XTS module only) The VV document will also include a summary of all errors or limitations of the software identified as a result of the VV. Arrow VV Package Details Arrows database file (Arrow5.dat dated 72314) is accurate for the following items: Steam, Ammonia, CO2, Air, H2, N2, O2 and He properties Fitting loss data Pipe Material databases are accurate for the following items: Pipe sizes (diameters, thickness) Pipe roughness Flow and pressures are accurately calculated using Arrows pipe and junction features. Each junction type will be checked against manual calculations for the different user options provided by Arrow. The Goal Seek and Control (GSC) module will be evaluated to determine that it produces correct and accurate results for the different Goal and Variable options Arrow provides (optional for GSC module only) This report will also include a summary of all bugs, errors, or limitations of the software identified as a result of the Verification process. Impulse VV Package Details The VV report will as a minimum verify the following: The following Pipe Material databases are accurate for Pipe sizes (diameters, thickness), Pipe roughness, Modulus of Elasticity: Steel ANSI.dat Stainless Steel ANSI.dat Stainless Tubing AFT Customary.dat PVC ASTM.dat Ductile Iron ANSI.dat Copper Tubing ASTM.dat Copper Pipe ASTM.dat PVDF AFT Customary.dat HDPE AFT Customary.dat Impulses database file is accurate for the following items: Water properties (density, viscosity, vapor pressure, Bulk Modulus) User fluid database function Fitting loss data Flow and pressures are accurately calculated using Impulses pipe and junction features. Various junction types will be checked against manual calculations for the different user options provided by Impulse. This report will also include a summary of all bugs, errors or limitations of the software identified as a result of the Verification process. Contact Archon at infoArchonEngineering.com to obtain a more specific range of use for the packages you are interested in.
0 Comments
Read More
Leave a Reply. |